Assertion

AssertionId
ITI83-020 Testable
predicate
When the Patient Identifier Cross-reference Manager does not recognize the Patient Identity Domain in the targetSystem, then the following failure shall be returned: - HTTP 403 (Forbidden) - An OperationOutcome Resource is returned indicating that the Patient Identity Domain is not recognized in an issue having: * severity: error * code: http://hl7.org/fhir/issue-type#code-invalid * diagnostics: “targetSystem not found”
Prescription level
Mandatory / Required / Shall
Page
20
Section
3.83.4.2.2.4
Status
to be reviewed
Last changed
1/7/20 2:49:31 PM by Anne-Gaëlle Bergé
Comment

Applies to

Actors

AIPOs

Audit Messages

Integration Profiles

Transactions

Standards

Covered by

Tests

Test Steps

Rules

MBV

Covered by (Deprecated)

Tests

Test Steps

Rules

Document name
Provenance
Revision
Action
IHE ITI PIXm SupplementIHE.net2.1