Details

    • Type: Technical task
    • Status: Closed
    • Priority: Critical
    • Resolution: Won't Fix
    • Affects Version/s: None
    • Fix Version/s: None
    • Labels:
      None
    • Severity:
      High - Feature does not work; unacceptable performance

      Description

      Some systems reject the HL7v2 message sent by Gazelle to share a patient. Different acknoledgments are

      MSH|^~\&|EHR_ITH-ICOSERVE_SIEMENS_INF_XUA|ITH-ICOSERVE_SIEMENS|Gazelle|IHE|20100413173312||ACK^A01|127117279248029||2.5 MSA|AR|20100413183235 ERR|||101||||No global identifier found in patient identifer list

      MSH|^~\&|XDSb_REG_ICT_topicus|ICT|Gazelle|IHE|20100413173346+0200||ACK^A01|OpenPIXPDQ127.0.0.1.20338765231571|P|2.3.1 MSA|AE|20100413183306 ERR|PID^1^3^204&Unknown Key Identifier

      Message sent:
      MSH|^~\&|Gazelle|IHE|EHR_ITH-ICOSERVE_SIEMENS_INF_XUA|ITH-ICOSERVE_SIEMENS|20100413183235||ADT^A01^ADT_A01|20100413183235|P|2.3.1 EVN|A01|20100413183235 PID|||RED103^^^RED&1.3.6.1.4.1.21367.3000.1.1&ISO||Langlois^Noe||19850115|M|||1-133 Rue Guer^^Sallanches^^74700^FRA||||||^CAT||103 PV1||I

        Attachments

          Activity

            People

            • Assignee:
              nlefebvr Nicolas Lefebvre
              Reporter:
              aberge Anne-Gaelle Berge
            • Votes:
              0 Vote for this issue
              Watchers:
              0 Start watching this issue

              Dates

              • Created:
                Updated:
                Resolved:

                Time Tracking

                Estimated:
                Original Estimate - Not Specified
                Not Specified
                Remaining:
                Remaining Estimate - 0 minutes
                0m
                Logged:
                Time Spent - 2 hours, 15 minutes
                2h 15m

                  Potential Duplicates