Uploaded image for project: 'Gazelle Test Management'
  1. Gazelle Test Management
  2. GZL-2155

In the share patient tab, when unticking the "Only Show Approved Configurations" check box; less systems are listed

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Critical
    • Resolution: Fixed
    • Affects Version/s: TestManagement-3.2-SR10
    • Fix Version/s: None
    • Labels:
      None

      Description

      In the share patient tab, when I select an actor for seeing the list of available systems, there is less systems displayed when I asked for approved and not approved configurations than when I ask for approved configurations only. I don't think it makes sense.
      For instance, in Pisa testing session, select a v2 message and then DOC_REGISTRY as actor. When the checkbox is tick I can see 8 systems, as soon as I untick the box, all of them disappear.
      Either the label is wrong, either the query is not well-formed.
      When I read "only show approved configurations", I understand that, if I uncheck the box, all the configurations will be displayed (approved and not approved).

        Attachments

          Activity

            People

            • Assignee:
              nlefebvr Nicolas Lefebvre
              Reporter:
              aberge Anne-Gaelle Berge
            • Votes:
              0 Vote for this issue
              Watchers:
              0 Start watching this issue

              Dates

              • Created:
                Updated:
                Resolved:

                Time Tracking

                Estimated:
                Original Estimate - Not Specified
                Not Specified
                Remaining:
                Remaining Estimate - 0 minutes
                0m
                Logged:
                Time Spent - 1 hour
                1h

                  Potential Duplicates