Uploaded image for project: 'Gazelle XUA Actors'
  1. Gazelle XUA Actors
  2. GZLXUA-12

Patient Manager X-Service Provider (XCPD Resp Gw) fails at handling the second request and followings

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Critical
    • Resolution: Fixed
    • Affects Version/s: 1.0.7
    • Fix Version/s: 1.0.9
    • Labels:
      None
    • Environment:
      validation.sequoiaproject.org
    • Account:
      Sequoia 2018 (SEQUOIA-201)

      Description

      When the module is integrated in Patient Manager.
      When you send a first (after deployment) ITI-55 with an XUA assertion, everything works well. In the contrary, all the following ones are causing a SOAP fault due to an connection exception when saving the information in the database.

        Attachments

          Activity

            People

            • Assignee:
              wbars Wylem Bars
              Reporter:
              aberge Anne-Gaelle Berge
            • Votes:
              0 Vote for this issue
              Watchers:
              2 Start watching this issue

              Dates

              • Created:
                Updated:
                Resolved:

                Time Tracking

                Estimated:
                Original Estimate - Not Specified
                Not Specified
                Remaining:
                Remaining Estimate - 0 minutes
                0m
                Logged:
                Time Spent - 1 day, 2 hours
                1d 2h

                  Potential Duplicates