Simulator Does Not Recognize LAB-29 OUL^R22

    Details

    • Type: Story
    • Status: Closed
    • Priority: High
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: 4.0.0
    • Component/s: None
    • Labels:
      None
    • Sprint:
      Sprint 18
    • Account:
      IICC-01 (IICC01)

      Description

      When an LAB-29 OUL^R22 message is sent to the simulator, the following acknowledge is received from the simulator:

      MSH|^~\&|OM_LAB_ANALYZER_MGR|IHE|OM_LAB_ANALYZER_MGR|IHE|20130716233845||ACK^R22^ACK|20130716233845|P|2.5.1||||||UNICODE UTF-8
      MSA|AE|PATIENT-0001
      ERR|||200|W||||The message type is not supported by the Analyzer Manager Simulator.

      In the HL7 Messages page on the website, the following details is displayed:

      The simulator has not been able to find a validator for the tuple (ANALYZER, LAB-27, OUL^R22^OUL_R22)

      Note that it references LAB-27 instead of LAB-29.