Uploaded image for project: 'PatientManager'
  1. PatientManager
  2. PAM-346

MSH-12 field for transaction ITI-30/ADT^A31^ADT_A05 message is incomplete for France domain

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Urgent
    • Resolution: Fixed
    • Affects Version/s: 9.3.3
    • Fix Version/s: 9.3.4
    • Component/s: PAMPDS
    • Labels:
      None
    • Sprint:
      2016 - S10
    • Account:
      InteropSante-BP6 (INTEROPBP6)

      Description

      When sending a ADT^A31^ADT_A05 message with "BP6 mode" enabled, the MSH-12 field is incomplete. The simulator sends 2.5 whereas 2.5^FRA^2.6 is expected.
      ADT^A28^ADT_A05 messages are correct but a double check for the other messages is needed

        Attachments

          Activity

            People

            Assignee:
            aberge Anne-Gaelle Berge
            Reporter:
            aberge Anne-Gaelle Berge
            Votes:
            0 Vote for this issue
            Watchers:
            1 Start watching this issue

              Dates

              Created:
              Updated:
              Resolved:

                Time Tracking

                Estimated:
                Original Estimate - 1 hour
                1h
                Remaining:
                Remaining Estimate - 0 minutes
                0m
                Logged:
                Time Spent - 1 hour
                1h

                  Potential Duplicates